{"product_id":"zoo-med-uvb-meter-unit","title":"Zoo Med UVB Meter Unit","description":"\u003ch2 data-start=\"36\" data-end=\"58\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp data-start=\"59\" data-end=\"496\"\u003eThe Zoo Med Digital UVB Meter is an essential tool for reptile owners seeking to maintain optimal UVB exposure in their enclosures. It accurately monitors UVB lamp output over time, helping prevent insufficient UVB levels that could compromise reptile health. Designed for ease of use, this meter provides precise, real-time readings of UVB intensity, ensuring that lamps deliver safe and effective ultraviolet radiation for your pets.\u003c\/p\u003e\n\u003ch2 data-start=\"498\" data-end=\"520\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"521\" data-end=\"1123\"\u003e\n\u003cli data-start=\"521\" data-end=\"577\"\u003e\n\u003cp data-start=\"523\" data-end=\"577\"\u003eAccurately tracks \u003cstrong data-start=\"541\" data-end=\"565\"\u003eUVB lamp degradation\u003c\/strong\u003e over time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"578\" data-end=\"680\"\u003e\n\u003cp data-start=\"580\" data-end=\"680\"\u003eDisplays UVB levels in \u003cstrong data-start=\"603\" data-end=\"648\"\u003emicrowatts per square centimetre (µW\/cm²)\u003c\/strong\u003e on an easy-to-read LCD screen\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"681\" data-end=\"740\"\u003e\n\u003cp data-start=\"683\" data-end=\"740\"\u003eSimple \u003cstrong data-start=\"690\" data-end=\"718\"\u003epoint-and-read operation\u003c\/strong\u003e with a round sensor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"741\" data-end=\"826\"\u003e\n\u003cp data-start=\"743\" data-end=\"826\"\u003eMaintains consistent measurement by recommending a uniform distance from the lamp\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"827\" data-end=\"884\"\u003e\n\u003cp data-start=\"829\" data-end=\"884\"\u003e\u003cstrong data-start=\"829\" data-end=\"861\"\u003ePre-installed 9-volt battery\u003c\/strong\u003e allows immediate use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"885\" data-end=\"964\"\u003e\n\u003cp data-start=\"887\" data-end=\"964\"\u003eBattery indicator signals when replacement is required to maintain accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"965\" data-end=\"1052\"\u003e\n\u003cp data-start=\"967\" data-end=\"1052\"\u003eSuitable for monitoring \u003cstrong data-start=\"991\" data-end=\"1014\"\u003erelative UVB output\u003c\/strong\u003e, not cross-lamp spectral comparison\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1053\" data-end=\"1123\"\u003e\n\u003cp data-start=\"1055\" data-end=\"1123\"\u003eCompact, lightweight, and portable for convenient enclosure checks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1125\" data-end=\"1149\"\u003eSpecifications\u003c\/h2\u003e\n\u003cul data-start=\"1150\" data-end=\"1681\"\u003e\n\u003cli data-start=\"1150\" data-end=\"1195\"\u003e\n\u003cp data-start=\"1152\" data-end=\"1195\"\u003e\u003cstrong data-start=\"1152\" data-end=\"1173\"\u003eMeasurement Type:\u003c\/strong\u003e UVB (Ultraviolet B)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1196\" data-end=\"1223\"\u003e\n\u003cp data-start=\"1198\" data-end=\"1223\"\u003e\u003cstrong data-start=\"1198\" data-end=\"1210\"\u003eDisplay:\u003c\/strong\u003e LCD Screen\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1224\" data-end=\"1256\"\u003e\n\u003cp data-start=\"1226\" data-end=\"1256\"\u003e\u003cstrong data-start=\"1226\" data-end=\"1247\"\u003eMeasurement Unit:\u003c\/strong\u003e µW\/cm²\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1257\" data-end=\"1304\"\u003e\n\u003cp data-start=\"1259\" data-end=\"1304\"\u003e\u003cstrong data-start=\"1259\" data-end=\"1276\"\u003ePower Source:\u003c\/strong\u003e 9-volt battery (included)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1305\" data-end=\"1345\"\u003e\n\u003cp data-start=\"1307\" data-end=\"1345\"\u003e\u003cstrong data-start=\"1307\" data-end=\"1329\"\u003eBattery Indicator:\u003c\/strong\u003e ‘Batt’ symbol\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1346\" data-end=\"1379\"\u003e\n\u003cp data-start=\"1348\" data-end=\"1379\"\u003e\u003cstrong data-start=\"1348\" data-end=\"1364\"\u003eSensor Type:\u003c\/strong\u003e Round sensor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1380\" data-end=\"1455\"\u003e\n\u003cp data-start=\"1382\" data-end=\"1455\"\u003e\u003cstrong data-start=\"1382\" data-end=\"1419\"\u003eRecommended Measurement Distance:\u003c\/strong\u003e Consistent distance (e.g., 30 cm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1456\" data-end=\"1530\"\u003e\n\u003cp data-start=\"1458\" data-end=\"1530\"\u003e\u003cstrong data-start=\"1458\" data-end=\"1484\"\u003eWarm-up Time Required:\u003c\/strong\u003e Minimum 5 minutes for lamps before readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1531\" data-end=\"1681\"\u003e\n\u003cp data-start=\"1533\" data-end=\"1681\"\u003e\u003cstrong data-start=\"1533\" data-end=\"1555\"\u003eCare Instructions:\u003c\/strong\u003e Clean with dry, soft cloth; avoid extreme temperatures, humidity, shock, or dust; protect sensor from light when not in use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1683\" data-end=\"1708\"\u003eRecommendations\u003c\/h2\u003e\n\u003cul data-start=\"1709\" data-end=\"2158\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-start=\"1709\" data-end=\"1782\"\u003e\n\u003cp data-start=\"1711\" data-end=\"1782\"\u003eAlways measure UVB at the \u003cstrong data-start=\"1737\" data-end=\"1753\"\u003ebasking site\u003c\/strong\u003e of your reptile enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1783\" data-end=\"1860\"\u003e\n\u003cp data-start=\"1785\" data-end=\"1860\"\u003eAllow UVB lamps to \u003cstrong data-start=\"1804\" data-end=\"1834\"\u003ewarm up at least 5 minutes\u003c\/strong\u003e before taking readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1861\" data-end=\"1921\"\u003e\n\u003cp data-start=\"1863\" data-end=\"1921\"\u003eWear \u003cstrong data-start=\"1868\" data-end=\"1898\"\u003eUV-blocking eye protection\u003c\/strong\u003e when checking lamps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1922\" data-end=\"2002\"\u003e\n\u003cp data-start=\"1924\" data-end=\"2002\"\u003eMaintain consistent measurement distance for accurate comparisons over time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2003\" data-end=\"2081\"\u003e\n\u003cp data-start=\"2005\" data-end=\"2081\"\u003eRegularly monitor lamps to determine the \u003cstrong data-start=\"2046\" data-end=\"2078\"\u003eoptimal replacement schedule\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2082\" data-end=\"2158\" data-is-last-node=\"\"\u003e\n\u003cp data-start=\"2084\" data-end=\"2158\" data-is-last-node=\"\"\u003eAvoid exposing the meter to harsh conditions to ensure long-term accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Zoo Med","offers":[{"title":"Default Title","offer_id":46434449358999,"sku":"097612003017","price":495.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/1979\/6631\/files\/Zoo_Med_UVB_Meter_Unit.jpg?v=1765629137","url":"https:\/\/petsupplycentral.com.au\/products\/zoo-med-uvb-meter-unit","provider":"Pet Supply Central","version":"1.0","type":"link"}